31. Bozzani A., Arici V., Bellinzona G.,
et al. Iatrogenic pulmonary artery rupture due to chest-tube insertion. Tex. Heart Inst. J., 2010. Vol. 37, № 6, p. 732–733.32. Calafiore A. M., Iacò A. L., Varone E.,
et al. Distorsion of the proximal circumflex artery during mitral valve repair. J. Card. Surg., 2010; 25:163–5.33. Dato A. G. M., Arslanian A., DuMarzio P.,
et al. Posttraumatic and iatrogenic forein bodies in the heart: report of fourteen cases and review of the literature. J. Thorac. Cardiovasc. Surg., 2003. Vol. 126, № 2, p. 408–414.34. DiMarco A., Nunez E., Osorio K.,
et al. Aortic perforation by active-fixation atrial pacing lead: an unusual but serious complication. Tex. Heart Inst., 2014. Vol. 41, № 3, p. 327–328.35. Doll N., Kiaii B., Borger M.,
et al. Five year results of 219 consecutive patients treated with extracorporeal membrane oxygenation for refractory postoperative cardiogenic shock. Ann. Thorac. Surg., 2004; 77:151–7.36. Fann J. I., Moffatt-Bruce S. D., DiMaio J. M., Sanchez J. A.
Human factors and human nature in cardiothoracic surgery. Ann. Thorac. Surg., 2016; 101:2059–2066.37. Funada A., Mizuno S., Ohsato K.,
et al. Three cases of iatrogenic coronary ostial stenosis after aortic valve replacement. Circulation J., 2006; 70:1312–7.38. Grande A. M., Fiore A., Massetti M., Vigano M.
Iatrogenic circumflex coronary artery lesion in mitral valve surgery. Tex. Heart Inst. J., 2008. Vol. 35, № 2, p. 179–183.39. Gummert J. F., Funkat A., Beckmann A.,
et al: Cardiac surgery in Germany during 2008. A report on behalf of the German Society for Thoracic and Cardiovascular Surgery. Thorac. Cardiovasc. Surg., 2009; 57:315–23.40. Hadjimiltiades S., Harokopos N., Papadopoulos C.,
et al: Left main coronary artery stenosis after aortic valve replacement. Hellenic J. Cardiol., 2005; 46:306–309.41. Hairston P., Simmeral Ch. P., Muller W. N.
Embolization of silastic ball from Starr-Edwards prostheses. Ann. Surg., 1967. Vol. 166, № 5, p. 817–819.42. Harries I., Chandrasekaran B., Barnes E., Ramcharitar S.
Iatrogenic mitral stenosis following transcatheter aortic valve replacement (TAVR). Indian Heart J., 2015. Vol. 67, p. 60–61.43. Hata M., Akiyama K., Orime Y.,
et al. Case of sudden death from retrograde type A dissection two days after surgery for a type B dissecting aneurism. Ann. Thorac. Surg., 2014. Vol. 20, p. 915.44. Jenicek M.
Medical error and harm: Understanding, prevention, and control. New York: A Productivity Press Taylor & Francis Group, 2011. P. 7.45. Kainuma S., Yamamoto H., Yamada Sh.,
et al. Iatrogenic injury of right coronary artery during tricuspid annuloplasty. 2017. Circ J doi: 10.1253/circj.CJ-17-0153.46. Kirchgesner T., Ghaye B., Marchandise S.,
et al. Iatrogenic cardiac perforation due to pacing lead displacement: imaging findings. Diagn. Intern. Imag. 2016. Vol. 97, p. 233–238.47. Lee W. M.
Iatrogenic bilateral pneumothorax arising from acupuncture: a case report. J. Orthopaedic Surg., 2005, 13: 300–302.48. Lillehei C. W., Bonnabeau R. C., Grossling S.
Removal of iatrogenic foreign bodies within cardiac chambers and great vessels. Circulation, 1965. Vol. 32, p. 782–787.49. Maltais S., El-Hamamsy I., Ducharme A.,
et al. Late iatrogenic coronary stenosis after selective intraoperative antegrade myocardial protection for stentless aortic valve replacement. J. Thorac. Cardiovasc. Surg., 2006. Vol. 132, № 2, p. 420–421.50. Martinez-Mora B., Cristobo-Sainz P. M., Nevado-Portero J., Dominguez-Petit A.
A case of acute iatrogenic atropine poisoning. Rev. Esp. Cardiol., 2011. Vol. 64, № 4, p. 342–348.51. Moss C. E., Fernandes-Caballero S., Walker D.
Atrio-oesophageal fistula after transcatheter radiofrequency ablation. BMJ. Case report, 2015, doi: 1136/bcr-2014-204998 1–4.52. Neri. E., Lisi G., Marchetti L., Sassi C.
Iatrogenic right ventricular laceration. Tex. Heart Inst. J., 2000; 27; 302–303.53. Ogboli-Nwassor E.
Medication errors in anaesthetic practice: a report of two cases and review of literature. Afr. Health Sciences, 2013. Vol. 13, № 3, p. 845–849.